Knowledge Base › Wiring guide: All-O-Matic Toro 24
Wiring guide: All-O-Matic Toro 24
This guide shows where each wire from the Nimbio terminal strip lands on the All-O-Matic Toro 24’s control board, and which relay setting Gate Status needs. Gate Status: wired. Sense 2 and SC connect across the board’s RELAY-1 contact, set to report the gate fully open, and Nimbio maps the relay’s two states to the labels shown in the app.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires Sense 2 and SC; Sense 1 is not used (see “Connections”).
- Power: PWR+ and PWR- land on the board’s +24VDC and GROUND terminals, rated up to 500 mA for accessories. The Nimbio board draws 40 to 70 mA.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | +24VDC | — | Toro 24 control board (LCD) | Rated up to 500 mA for accessories. |
| PWR- | GROUND | — | Toro 24 control board (LCD) | |
| Sense 2 | RELAY-1 N.O. | — | Toro 24 control board (LCD) | RELAY-1 contact; behavior set to OPENED SIGNAL from the LCD menu. |
| SC | RELAY-1 COM | — | Toro 24 control board (LCD) | Sense common; the other side of the RELAY-1 contact from Sense 2. |
| Sense 1 | Not used | — | — | Not used. RELAY-1 is a single N.O./COM contact, and one contact reports one state. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | COMMON | — | Toro 24 control board (LCD) | The COMMON directly above EXIT. |
| NO | EXIT | — | Toro 24 control board (LCD) |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
The RELAY-1 contact’s behavior is chosen from the Toro 24’s LCD menu. This guide sets it to OPENED SIGNAL: active when the gate is fully open (CLOSED SIGNAL is the alternative). Confirm the setting for your site with Nimbio support during installation.
Gate Status
Gate Status: wired. Sense 2 and SC connect across the RELAY-1 contact, set to OPENED SIGNAL: active when the gate is fully open. Nimbio maps the relay’s two states to the labels shown in the app. Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed.
No suitable output on your operator? A magnetic gate switch can report the gate’s position instead: wire its two leads to Sense 1 and SC for fully closed, or to Sense 2 and SC for fully open. The switch must be a dry contact that puts out no power of its own; if yours puts out power, add a relay that turns it into a dry contact.
Frequently asked questions
Need help on site?
Our support team provides live phone assistance during installation.