Knowledge Base › Wiring guide: Amazing Gates 900 HD

Wiring guide: Amazing Gates 900 HD

This guide shows where each wire from the Nimbio terminal strip lands on the Amazing Gates 900 HD’s control board. Gate Status: not supported. The manual documents lock and alarm outputs only, with no gate-position output, so this guide does not wire Sense 1, Sense 2, SC or NC.

Printable version (PDF)

Before you start

  • Power the operator down at its supply before touching any terminal.
  • The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
  • Power: PWR+ and PWR- land on terminals 10 (24V DC output, 1 A maximum) and 11 (GND).
  • You need a small screwdriver for the terminal screws.
Gate Status: not available on this operator Nimbio PWR+ PWR- Sense 2 SC Sense 1 NC C NO Relay shown de-energized: NO open, NC closed AG900HD control board 24V DC output (10) GND (11) COM (5) Swipe Card (4) 1 → 24V DC output PWR+ 2 → GND PWR- 4 → Swipe Card NO 3 → COM C Legend 1. Nimbio PWR+ (red) → 24V DC output (10) on the AG900HD control board 2. Nimbio PWR- (black) → GND (11) on the AG900HD control board 3. Nimbio C (grey) → COM (5) on the AG900HD control board 4. Nimbio NO (green) → Swipe Card (4) on the AG900HD control board NC: Not used Sense 1: Not used Sense 2: Not used SC: Not used Cautions Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed. Wire colors PWR+ — red PWR- — black Sense 2 — yellow/green stripe SC — black/white stripe Sense 1 — yellow NC — blue C — grey NO — green
Nimbio terminal strip (left) to the AG900HD control board (right). Wire tags name the destination terminal. On a phone, scroll the diagram sideways or pinch to zoom; the Connections list below has every wire.

Connections

Nimbio terminalOperator terminalNumberBoardNote
PWR+24V DC output10AG900HD control board24V DC output, 1 A maximum.
PWR-GND11AG900HD control board
Sense 2Not used——Not used in this guide.
SCNot used——Not used in this guide.
Sense 1Not used——Not used in this guide.
NCNot used——Not used: the operator input is wired to NO and C.
CCOM5AG900HD control board
NOSwipe Card4AG900HD control board

PWR+

Operator terminal: 24V DC outputNumber: 10Board: AG900HD control boardNote: 24V DC output, 1 A maximum.

PWR-

Operator terminal: GNDNumber: 11Board: AG900HD control boardNote:

Sense 2

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

SC

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

Sense 1

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

NC

Operator terminal: Not usedNumber: —Board: —Note: Not used: the operator input is wired to NO and C.

C

Operator terminal: COMNumber: 5Board: AG900HD control boardNote:

NO

Operator terminal: Swipe CardNumber: 4Board: AG900HD control boardNote:

When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.

Settings on the operator

No operator setting is changed by this guide.

Gate Status

Gate Status: not available on this operator. The 900 HD’s terminal list documents lock outputs and alarm outputs only; no gate-position or limit-switch output exists, so Sense 1, Sense 2, SC and NC stay unwired. Contact Nimbio support if your installation needs Gate Status.

Frequently asked questions

Does this guide give Gate Status on the Amazing Gates 900 HD? +

No. The manual documents no gate-position output on this control board, only lock and alarm outputs, so Sense 1, Sense 2, SC and NC are not wired. Contact Nimbio support if you need Gate Status on this gate.

Which Nimbio terminals open the gate on the Amazing Gates 900 HD? +

NO and C, wired to the Swipe Card terminal (4) and COM (5). The Nimbio relay closes NO to C, which the 900 HD reads as an open command.

Is the Nimbio NC terminal used on the Amazing Gates 900 HD? +

No. The operator input takes the NO and C pair, so NC stays empty.

Related articles

Need help on site?

Our support team provides live phone assistance during installation.

Call 800‑353‑3422 Send a message