Knowledge Base › Wiring guide: Amazing Gates 900 HD
Wiring guide: Amazing Gates 900 HD
This guide shows where each wire from the Nimbio terminal strip lands on the Amazing Gates 900 HD’s control board. Gate Status: not supported. The manual documents lock and alarm outputs only, with no gate-position output, so this guide does not wire Sense 1, Sense 2, SC or NC.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- land on terminals 10 (24V DC output, 1 A maximum) and 11 (GND).
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | 24V DC output | 10 | AG900HD control board | 24V DC output, 1 A maximum. |
| PWR- | GND | 11 | AG900HD control board | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | COM | 5 | AG900HD control board | |
| NO | Swipe Card | 4 | AG900HD control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
No operator setting is changed by this guide.
Gate Status
Gate Status: not available on this operator. The 900 HD’s terminal list documents lock outputs and alarm outputs only; no gate-position or limit-switch output exists, so Sense 1, Sense 2, SC and NC stay unwired. Contact Nimbio support if your installation needs Gate Status.