Knowledge Base › Wiring guide: Nice Apollo 835/836

Wiring guide: Nice Apollo 835/836

This guide shows where each wire from the Nimbio terminal strip lands on the Nice Apollo 835/836 gate control board. Gate Status: not wired in this guide. The board has a Master Operator Indicator output, but it is a voltage output rather than a dry contact, so this guide does not wire Sense 1, Sense 2, SC or NC.

Printable version (PDF)

Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.

Before you start

  • Power the operator down at its supply before touching any terminal.
  • The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
  • Power: PWR+ and PWR- go to a separate power supply, not the operator board. The 835/836’s 12V terminal tracks the operator’s battery rather than being a stable accessory output. The Nimbio accepts 6.5 to 24 V AC or DC.
  • You need a small screwdriver for the terminal screws.
Gate Status: not wired in this guide Nimbio PWR+ PWR- Sense 2 SC Sense 1 NC C NO Relay shown de-energized: NO open, NC closed Separate power supply Supply + (+) Supply – (-) 835/836 gate control board GND (8) FREE EXIT (10) 1 → Supply + PWR+ 2 → Supply – PWR- 4 → FREE EXIT NO 3 → GND C Legend 1. Nimbio PWR+ (red) → Supply + (+) on the Separate power supply 2. Nimbio PWR- (black) → Supply – (-) on the Separate power supply 3. Nimbio C (grey) → GND (8) on the 835/836 gate control board 4. Nimbio NO (green) → FREE EXIT (10) on the 835/836 gate control board NC: Not used Sense 1: Not used Sense 2: Not used SC: Not used Cautions The 835/836’s 12V terminal is ‘Supplied Battery Voltage’ — it tracks the operator’s battery rather than being a stable accessory output. Give the Nimbio its own power supply. Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed. Wire colors PWR+ — red PWR- — black Sense 2 — yellow/green stripe SC — black/white stripe Sense 1 — yellow NC — blue C — grey NO — green
Nimbio terminal strip (left) to the 835/836 gate control board (right). Wire tags name the destination terminal. On a phone, scroll the diagram sideways or pinch to zoom; the Connections list below has every wire.

Connections

Nimbio terminalOperator terminalNumberBoardNote
PWR+Supply ++Separate power supplyDo not power from the operator board — see “Before you start.”
PWR-Supply ––Separate power supply
Sense 2Not used——Not used in this guide.
SCNot used——Not used in this guide.
Sense 1Not used——Not used in this guide.
NCNot used——Not used: the operator input is wired to NO and C.
CGND8835/836 gate control board
NOFREE EXIT10835/836 gate control board

PWR+

Operator terminal: Supply +Number: +Board: Separate power supplyNote: Do not power from the operator board — see “Before you start.”

PWR-

Operator terminal: Supply –Number: –Board: Separate power supplyNote:

Sense 2

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

SC

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

Sense 1

Operator terminal: Not usedNumber: —Board: —Note: Not used in this guide.

NC

Operator terminal: Not usedNumber: —Board: —Note: Not used: the operator input is wired to NO and C.

C

Operator terminal: GNDNumber: 8Board: 835/836 gate control boardNote:

NO

Operator terminal: FREE EXITNumber: 10Board: 835/836 gate control boardNote:

When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.

Settings on the operator

No operator setting is changed by this guide.

Gate Status

Gate Status: not wired in this guide. The 835/836 board’s Master Operator Indicator switches between +12 V and ground depending on the gate’s closed-limit position, but that is a voltage output, not a dry contact, so the Nimbio’s sense lines are not connected to it here. Contact Nimbio support if your installation needs Gate Status wired for this operator.

Frequently asked questions

Does this guide give Gate Status on the Nice Apollo 835/836? +

No. The board’s position output is a voltage signal rather than a dry contact, so it is not wired here. Contact Nimbio support if you need Gate Status on this gate.

Which Nimbio terminals open the gate on the Nice Apollo 835/836? +

NO and C, wired to FREE EXIT (terminal 10) and GND (terminal 8). The Nimbio relay closes NO to C, which the 835/836 reads as an open command.

Is the Nimbio NC terminal used on the Nice Apollo 835/836? +

No. The operator input takes the NO and C pair, so NC stays empty.