Knowledge Base › Wiring guide: Nice Apollo 835/836
Wiring guide: Nice Apollo 835/836
This guide shows where each wire from the Nimbio terminal strip lands on the Nice Apollo 835/836 gate control board. Gate Status: not wired in this guide. The board has a Master Operator Indicator output, but it is a voltage output rather than a dry contact, so this guide does not wire Sense 1, Sense 2, SC or NC.
Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- go to a separate power supply, not the operator board. The 835/836’s 12V terminal tracks the operator’s battery rather than being a stable accessory output. The Nimbio accepts 6.5 to 24 V AC or DC.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | Supply + | + | Separate power supply | Do not power from the operator board — see “Before you start.” |
| PWR- | Supply – | – | Separate power supply | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | GND | 8 | 835/836 gate control board | |
| NO | FREE EXIT | 10 | 835/836 gate control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
No operator setting is changed by this guide.
Gate Status
Gate Status: not wired in this guide. The 835/836 board’s Master Operator Indicator switches between +12 V and ground depending on the gate’s closed-limit position, but that is a voltage output, not a dry contact, so the Nimbio’s sense lines are not connected to it here. Contact Nimbio support if your installation needs Gate Status wired for this operator.