Knowledge Base › Wiring guide: Beninca HEADY

Wiring guide: Beninca HEADY

This guide shows where each wire from the Nimbio terminal strip lands on the Beninca HEADY control unit. Gate Status: wired. Sense 1 and SC connect across the SCA contact (terminals 16-17), and Nimbio maps the relay’s two states to the labels shown in the app.

Printable version (PDF)

Before you start

  • Power the operator down at its supply before touching any terminal.
  • The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires Sense 1 and SC; Sense 2 is not used (see “Connections”).
  • Power: PWR+ and PWR- land on terminals 14 and 15 (24 VAC accessory power, 500 mA maximum). The Nimbio board draws 40 to 70 mA.
  • You need a small screwdriver for the terminal screws.
Gate Status: wired on this board Nimbio PWR+ PWR- Sense 2 SC Sense 1 NC C NO Relay shown de-energized: NO open, NC closed HEADY control unit 24 VAC (14) 24 VAC (15) SCA (17) SCA (16) COM (26) PED (22) 1 → 24 VAC PWR+ 2 → 24 VAC PWR- 6 → PED NO 5 → COM C 4 → SCA Sense 1 3 → SCA SC Legend 1. Nimbio PWR+ (red) → 24 VAC (14) on the HEADY control unit 2. Nimbio PWR- (black) → 24 VAC (15) on the HEADY control unit 3. Nimbio SC (black/white stripe) → SCA (17) on the HEADY control unit 4. Nimbio Sense 1 (yellow) → SCA (16) on the HEADY control unit 5. Nimbio C (grey) → COM (26) on the HEADY control unit 6. Nimbio NO (green) → PED (22) on the HEADY control unit NC: Not used Sense 2: Not used Cautions Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed. Wire colors PWR+ — red PWR- — black Sense 2 — yellow/green stripe SC — black/white stripe Sense 1 — yellow NC — blue C — grey NO — green
Nimbio terminal strip (left) to the HEADY control unit (right). Wire tags name the destination terminal. On a phone, scroll the diagram sideways or pinch to zoom; the Connections list below has every wire.

Connections

Nimbio terminalOperator terminalNumberBoardNote
PWR+24 VAC14HEADY control unit24 VAC accessory power, 500 mA maximum.
PWR-24 VAC15HEADY control unit
Sense 2Not used——Not used. SCA is a single N.O. contact, and one contact reports one state.
SCSCA17HEADY control unitSense common; the other side of the SCA contact from Sense 1.
Sense 1SCA16HEADY control unitSCA contact; open-gate indicator.
NCNot used——Not used: the operator input is wired to NO and C.
CCOM26HEADY control unit
NOPED22HEADY control unitOpens motor 1 fully.

PWR+

Operator terminal: 24 VACNumber: 14Board: HEADY control unitNote: 24 VAC accessory power, 500 mA maximum.

PWR-

Operator terminal: 24 VACNumber: 15Board: HEADY control unitNote:

Sense 2

Operator terminal: Not usedNumber: —Board: —Note: Not used. SCA is a single N.O. contact, and one contact reports one state.

SC

Operator terminal: SCANumber: 17Board: HEADY control unitNote: Sense common; the other side of the SCA contact from Sense 1.

Sense 1

Operator terminal: SCANumber: 16Board: HEADY control unitNote: SCA contact; open-gate indicator.

NC

Operator terminal: Not usedNumber: —Board: —Note: Not used: the operator input is wired to NO and C.

C

Operator terminal: COMNumber: 26Board: HEADY control unitNote:

NO

Operator terminal: PEDNumber: 22Board: HEADY control unitNote: Opens motor 1 fully.

When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.

Settings on the operator

No operator setting is changed by this guide.

Gate Status

Gate Status: wired. Sense 1 (terminal 16) and SC (terminal 17) connect across the SCA contact. The contact is closed while the gate is open, pulses during movement, and is open while the gate is closed; Nimbio maps its states to the labels shown in the app. Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed.

No suitable output on your operator? A magnetic gate switch can report the gate’s position instead: wire its two leads to Sense 1 and SC for fully closed, or to Sense 2 and SC for fully open. The switch must be a dry contact that puts out no power of its own; if yours puts out power, add a relay that turns it into a dry contact.

Frequently asked questions

Does the Beninca HEADY need an expansion board for Gate Status? +

No. Sense 1 and SC land on the SCA contact of the main HEADY control unit, terminals 16 and 17.

Which Nimbio terminals open the gate on the Beninca HEADY? +

NO and C, wired to PED (terminal 22) and COM (terminal 26). PED opens motor 1 fully; a separate Step-by-Step input (23) is not wired by this guide.

Why is Sense 2 not used on the Beninca HEADY? +

Terminals 16 and 17 are the two sides of one SCA contact. One contact reports one state, so Sense 1 and SC across it is the complete connection.

Is the Nimbio NC terminal used on the Beninca HEADY? +

No. The operator input takes the NO and C pair, so NC stays empty.

Related articles

Need help on site?

Our support team provides live phone assistance during installation.

Call 800‑353‑3422 Send a message
Call Now