Knowledge Base › Wiring guide: LiftMaster LA400
Wiring guide: LiftMaster LA400
This guide shows where each wire from the Nimbio terminal strip lands on the LiftMaster LA400’s main control board. Gate Status: needs the expansion board. This guide wires the open command and power only, so the Nimbio app does not show whether this gate is open or closed with this wiring.
Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- go to a separate 12-24 V AC or DC power supply, not to the operator board. The board’s accessory output is rated 500 mA, but Nimbio installations powered from this board have had unstable power. The Nimbio board draws 40 to 70 mA.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | Supply + | + | Separate power supply | Do not power from the operator board — see “Before you start.” |
| PWR- | Supply – | – | Separate power supply | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | EXIT | — | LA400 main control board | Shares the Exit pair with NO. |
| NO | EXIT | — | LA400 main control board | Soft open command. |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
No operator setting is changed by this guide.