Knowledge Base › Wiring guide: Mighty Mule MM371W and MM372W
Wiring guide: Mighty Mule MM371W and MM372W
This guide shows where each wire from the Nimbio terminal strip lands on the MM371W/MM372W control board. Gate Status: wired via the AUX relay, which reports whether the gate is operating or at rest, not whether it is open or closed.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires Sense 1 and SC; Sense 2 is not used (see “Connections”).
- Power: PWR+ and PWR- land on AUX V+ and AUX V-, which draw from the operator’s own battery. On a solar-powered gate, use a separate supply instead — see Cautions. The Nimbio accepts 6.5 to 24 V AC or DC.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | AUX V+ | — | MM371W/MM372W control board | Draws from the operator’s own battery — see Cautions for solar sites. |
| PWR- | AUX V- | — | MM371W/MM372W control board | |
| Sense 2 | Not used | — | — | Not used. The AUX relay is a single contact reporting operation vs. rest; a second sense line on it would only mirror Sense 1. |
| SC | AUX C | — | MM371W/MM372W control board | Sense common; the other side of the AUX relay from Sense 1. |
| Sense 1 | AUX NO | — | MM371W/MM372W control board | AUX relay; active only while the gate is operating. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | COM | — | MM371W/MM372W control board | |
| NO | EXIT | — | MM371W/MM372W control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
No operator setting is changed by this guide.
Gate Status
Gate Status: wired. Sense 1 and SC connect across the AUX relay, which activates during gate operation and stays activated for the duration of the operation. Sense 1 reports whether the gate is moving or at rest, and Nimbio maps those two states to the labels shown in the app. Sense-line polarity does not depend on the wiring. Nimbio maps each sense line’s triggered and untriggered state to an Open or Closed label after installation. If Gate Status shows the opposite of the physical gate, contact Nimbio support to have the labels switched; no rewiring is needed.
No suitable output on your operator? A magnetic gate switch can report the gate’s position instead: wire its two leads to Sense 1 and SC for fully closed, or to Sense 2 and SC for fully open. The switch must be a dry contact that puts out no power of its own; if yours puts out power, add a relay that turns it into a dry contact.