Wiring guide: Viking G-5
This guide shows where each wire from the Nimbio terminal strip lands on the Viking G-5’s control board. Gate Status: not wired in this guide. The G-5’s Magnetic Lock output is typically a powered circuit that needs a separate switch before Nimbio can read it, so the Nimbio app does not show whether this gate is open or closed with this wiring.
Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.
Before you start
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- go to a separate 12-24 V AC or DC power supply, not to the operator board’s 24VDC accessory output.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | Supply + | — | Separate power supply | |
| PWR- | Supply – | — | Separate power supply | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | GND | — | G-5 control board | |
| NO | Exit | — | G-5 control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Settings on the operator
No operator setting is changed by this guide.
Gate Status
Gate Status: not wired in this guide. The G-5’s Magnetic Lock output changes state at the closed limit, but it is typically a powered (wet) circuit meant to energize a 24 V maglock coil. It cannot connect to Nimbio’s sense inputs without a separate switch (a relay), which this guide does not cover. If you need Gate Status on a G-5, contact Nimbio support before wiring.