Knowledge Base › Wiring guides › Viking G-5
Wiring guide: Viking G-5
This guide shows where each wire from the Nimbio terminal strip lands on the Viking G-5’s control board. Gate Status: not wired in this guide. The G-5’s Magnetic Lock output is typically a powered circuit that needs a separate switch before Nimbio can read it, so the Nimbio app does not show whether this gate is open or closed with this wiring.
Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.
Before you start
We recommend having a licensed professional gate or low-voltage technician install your Nimbio device. Our support team can also work directly with property owners or their personnel if they prefer to install it themselves.
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- go to a separate 12-24 V AC or DC power supply, not to the operator board’s 24VDC accessory output.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | Supply + | — | Separate power supply | |
| PWR- | Supply – | — | Separate power supply | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | GND | — | G-5 control board | |
| NO | Exit | — | G-5 control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
Settings on the operator
No operator setting is changed by this guide.
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Gate Status
Gate Status: not wired in this guide. The G-5’s Magnetic Lock output changes state at the closed limit, but it is typically a powered (wet) circuit meant to energize a 24 V maglock coil. It cannot connect to Nimbio’s sense inputs without a separate switch (a relay), which this guide does not cover. If you need Gate Status on a G-5, contact Nimbio support before wiring.