Knowledge Base › Wiring guides › Viking H-10
Wiring guide: Viking H-10
This guide shows where each wire from the Nimbio terminal strip lands on the Viking H-10’s control board. Gate Status: not wired in this guide. The H-10 has no gate-position output, so the Nimbio app does not show whether this gate is open or closed with this wiring.
Note: This operator cannot supply enough continuous power for Nimbio. Use a separate 12–24V AC or DC power supply.
Before you start
We recommend having a licensed professional gate or low-voltage technician install your Nimbio device. Our support team can also work directly with property owners or their personnel if they prefer to install it themselves.
- Power the operator down at its supply before touching any terminal.
- The Nimbio terminal strip has eight terminals: PWR+, PWR-, Sense 2, SC, Sense 1, NC, C and NO. This guide wires PWR+, PWR-, C and NO; the other four stay empty.
- Power: PWR+ and PWR- go to a separate power supply; this operator needs an external power source for the Nimbio. The Nimbio accepts 6.5 to 24 V AC or DC.
- You need a small screwdriver for the terminal screws.
Connections
| Nimbio terminal | Operator terminal | Number | Board | Note |
|---|---|---|---|---|
| PWR+ | Supply + | — | Separate power supply | |
| PWR- | Supply – | — | Separate power supply | |
| Sense 2 | Not used | — | — | Not used in this guide. |
| SC | Not used | — | — | Not used in this guide. |
| Sense 1 | Not used | — | — | Not used in this guide. |
| NC | Not used | — | — | Not used: the operator input is wired to NO and C. |
| C | Gnd | — | H-10 control board | |
| NO | Exit | — | H-10 control board |
PWR+
PWR-
Sense 2
SC
Sense 1
NC
C
NO
Settings on the operator
No operator setting is changed by this guide.
When the wiring is done, restore power at the supply. A Nimbio support team member then calls to test the gate before you close the panel.
Gate Status
Gate Status: not wired in this guide. This operator has no gate-position output; its Mag. Lock relay is a lock-control output, not a gate-position output. If you need Gate Status on an H-10, contact Nimbio support before wiring.
Frequently asked questions
Need help on site?
Our support team provides live phone assistance during installation.